Home » Atomic Absorption Spectrophotometer

Shimadzu AA-6300 / AA-6800 / AA-7000 AAS Service

Shimadzu AA-6300 / AA-6800 / AA-7000 / AA-6200 · Repair · Calibration · AMC · Pan-India courier support

Shimadzu AA-7000 and AA-6200 atomic absorption spectrophotometer service

Shimadzu AA-series spectrophotometers from the AA-6200 through the AA-7000 are widely used across pharma, environmental and metallurgical labs in India. We provide complete flame and furnace support for the series: ignition and gas controller faults, GFA graphite furnace issues, autosampler service and the WizAArd software interface, with component-level electronics repair where boards have failed.

Common Shimadzu AA-6300 / AA-6800 / AA-7000 / AA-6200 Problems We Fix

  • Ignition failure or flame safety errors on startup
  • GFA graphite furnace temperature or tube errors
  • ASC autosampler arm alignment and injection faults
  • WizAArd software cannot connect to the instrument
  • Low sensitivity in flame or furnace mode
  • Burner head corrosion, drain and interlock faults

How Our Service Works

  1. Telephonic triage of the error code and behaviour
  2. On-site or lab service with courier support
  3. Gas controller, ignition and interlock repair; furnace and autosampler service
  4. Optics and lamp alignment, detector verification
  5. Sensitivity verification and documentation for your QA records

Frequently Asked Questions

Do you service both flame and graphite furnace configurations?

Yes — both flame AAS and GFA graphite furnace systems, including furnace temperature calibration and tube/contact service.

Our AA-6300 fails its safety self-check. Is that repairable?

Safety interlock and gas-controller faults are among the most common AA-series problems and are generally repairable at board or sensor level.

Can you train our operators after service?

Yes — post-service demonstration and operator guidance are part of the handover, as our review from a state agriculture lab notes.

Get a Free Quote for Your Shimadzu AA-6300 / AA-6800 / AA-7000 / AA-6200

Tell us the model and the fault — we give a free telephonic diagnosis before anything ships. NABL-accredited calibration, component-level repair and insured courier pickup across India.

About Our Atomic Absorption Spectrophotometer Services

Flame ignition failures, gas-box errors, lamp alignment and sensitivity loss — our atomic absorption spectrophotometer repair service covers the Shimadzu AA-6300 / AA-6800 / AA-7000 / AA-6200 end to end. Instruments Care engineers service AAS systems for universities, soil-testing laboratories, pharmaceutical QC and metal industries across India, including discontinued models whose factory support has ended.

Every serviced Shimadzu AA-6300 / AA-6800 / AA-7000 / AA-6200 is verified with standard solutions before return: burner and nebuliser cleaned, safety interlocks tested, hollow-cathode lamps aligned and sensitivity restored to the cookbook value. Spares for legacy models are sourced or repaired at component level, and AMC plans keep flame and furnace systems dependable through the year.

Call +91 95000 10101 or write to info@instrumentscare.com for a free telephonic diagnosis and a same-day quote. Instrument pickup by insured courier is available from every state in India, and on-site visits cover Chennai, Tamil Nadu and most of South India.

Other Instruments We Service

WhatsApp Chat